YSAV70B Medical Ventilator with air compressor hospital respirator ventilator machine

FOB Reference Price:Get Latest Price
$3,500.00 - $4,000.00 / Sets | 1 Set/Sets for Respirator (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Brand Name:
YSENMED
Model Number:
YSAV70B
Place of Origin:
Guangdong, China
Maximum Minute ventilation:
≥18L / min
Respiratory Rate:
1 ~ 99 bpm
safety valve:
<12.5 kPa
Oxygen concentrator:
21% ~ 100% adjustable
modes of ventilation:
A/C, SIPPV,IPPV,SIMV,PSIMV,CPAP,PCV,PEEP,SIGN,SPONT, MANUAL
PEEP:
0 ~ 1.0 kPa
IMV frequency:
1~20 bpm
Ventilator compliance:
≤30 Ml/kPa
Mode:
pneumatically powered and electrically controlled system
Certificate:
CE ISO
Type:
Respiratory Equipments Accessories
Supply Ability
Supply Ability:
1000 Set/Sets per Month Respirator
Packaging & Delivery
Packaging Details
Standard export wooden package for ventilator machine
Port
Guangzhou
Lead Time :
Within 10-15 working days after payment

YSAV70B Medical Ventilator with air compressor hospital                  respirator ventilator machine  

Product description

 

TECHNIQUES SPECIFICATIONS
Physical specifications 
Display 10.4'' LCD Display
Mode:pneumatically powered and electrically controlled system
Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Technical Specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa
safety valve <12.5  kPa
Respiratory Rate1 ~ 99 bpm
Oxygen Concentration21% ~ 100%  
Maximum Minute ventilation≥18L / min
modes of ventilationA/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT
Ventilator compliance≤30 Ml/kPa
PEEP:0 ~ 1.0 kPa
Ptr: -10 ~ 10 hPa
IMV frequency:1~20 bpm
I/E Ratio:4:1~1:4, Has the inverse ratio ventilation
Tidal VolumeSetting Range:  50~1500ML   Display Range: 0~2000ml ;  resolution ratio: 10ml
Inspiratory Plateau:0~1s
Maximum Safety  Pressure≤ 6.0kPa
Sigh: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point
Pressure limit range:1.0~ 6.0kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicatingLower: 0.1 kPa ~ 6.0 kPa;   Upper: 0 ~ 5.0  kPa
±0.2 kPa
Ventilation Volume alarm: ≥ 18L/ MIN 
Power Supply AlarmAc/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature: 10 ~ 40oC
Relative humidity:no higher than 80 %
Atmospheric pressure:860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz;  
Attention: the AC power supply used for the anesthesia machine must be well   grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. 
Storage
Ambient temperature: -15oC ~ +50oC
Relative humidity: no higher than 95 %
Atmospheric pressure: 86 kPa ~ 106 kPa.
 It should be stored in a room without corrosive gas and well ventilated
Package
packaging boxcomply with the requirement of GB/T 15464
 Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
 Moisture protection and rain protection to ensure that product is protected from natural damage. 
Safty & Alarm
Gas source pressureImmediate alarm; “high level alarm” indicator flickers raising an audible alarm.
Airway Pressure AlarmThe airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm. 
Tidal Volume AlarmLower than 50ml, The alarm will be raised after one breathing cycle. 
Ventilation Volume AlarmLower: 0~12L/Min;   Up: 18L/ Min
Battery Voltage AlarmIt alrms when the battery voltage is lower than 10.5V.
Power On Self TestSelf test before working, assure it's working normally. 
PACKAGE INCLUDED 
QTYNAME
1 setMain unit
1 setOxygen tube
2 setSilicone Mask
1 pcPower line
4 pcsThreaded pipe
2 pcsStandard Pipe
1 setOxygen Reducer
1 setHumidifier
1 pcBattery
2 setflow sensor
2 pcsA leather bag ( Blue)
1 setTools with the machine
1 setUser Manual (English Version)

 

 

Product display

 

More products
About Us

 

Certifications

 

Delivery & Payment

 

Contact us
You May Like
Not exactly what you want? 1 request, multiple quotations Get Quotations Now >>
You May Like